Powersolve HEATSINKS Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Fontes de alimentação Powersolve HEATSINKS. Powersolve HEATSINKS User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 2
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
www.powersolve.co.uk
High Density DC-DC Modules
Heat Sinks
For the following DC-DC Converter modules
- PS50, PS50W
- PS75, PS75W, PSQ75, PSQ75W, PS75-Dual
- PS100, PS100W, PSQ100W
- PS150, PS150W
- PS200, PS200W
Thermal pad, screws & washers included
Half Brick Case Heatsink
Vertical Fins
Model No.: M-C308
Horizontal Fins (Short)
Model No.: M-C091
Horizontal Fins (Long)
Model No.: M-C092
Rca: 3.9°C/W, At natural convection
1.74°C/W, At 100LFM
1.33°C/W, At 200LFM
1.12°C/W, At 300LFM
0.97°C/W, At 400LFM
Rca: 4.7°C/W, At natural convection
2.89°C/W, At 100LFM
2.30°C/W, At 200LFM
1.88°C/W, At 300LFM
1.59°C/W, At 400LFM
Rca: 3°C/W, At natural convection
1.44°C/W, At 100LFM
1.17°C/W, At 200LFM
1.04°C/W, At 300LFM
0.95°C/W, At 400LFM