Specification
1.5-6.0 kVA
True On-Line UPS
Complete UPS Cabinet
Single / Dual Mains Input Option
Internal Maintenance Bypass Switch Option
LCD Load Segment Control 2.5 kVA & 3.0 kVA
Optional 10 Year Batteries
XC Series
Input
Input Voltage (full load 115 VAC version, 80-138 V
without using battery) 208 VAC version, 176-276 V
230 VAC version, 176-276 V
Input Frequency 46-64 Hz
Input Power Factor <0.98 at full load
Input Protection Fuse/Breaker
Output
Output Voltage 115 VAC nominal -
100/110/115/120 VAC selectable
208 VAC nominal -
208/220/230/240 VAC selectable
230 VAC nominal -
208/220/230/240 VAC selectable
Output Regulation ±2% of nominal
Output Waveform Sine wave
Output THD <3%, linear load
Crest Factor 3:1
Output Protection Electronic overload protection
(ultimately by fuse/breaker)
Efficiency (AC-AC) 86% up to 1.5 kVA, 90% up to 6.0 kVA
Overload Capacity See Xi Datasheet
Output Frequency 50/60 Hz dependent on input
Battery
Internal Battery Type VRLA 5 year design life standard,
10 year design life option available
Battery Replacement Hot-swap all models
Recharge <4 hours to 90%, standard battery only
Battery String Voltage 48 VDC: 1.5 kVA
96 VDC: 2.5-3.0 kVA
192 VDC: 4.0-6.0 kVA
Autonomy See Xi Datasheet
Temperature Autonomy, recharge and battery life
based on +25 ºC ambient
1
General
Input/Output Terminals Suitable for cable up to 10 mm
2
Display/Alarm Front panel LCD menu driven, audible
alarms. See System Layout
Interface VFC Standard (AS400) providing remote
indication of: UPS AC Input OK/ UPS AC
Input
Failure Battery OK/ Battery Low UPS OK/
UPS Alarm On Inverter /UPS Bypassed
RS232 or USB option available
REPO Remote emergency power off, must be
fitted for unit to function. Remove link to
shut down output in AC mode or shut
down unit in battery mode
Mechanical (h x w x d) Small - 1200 mm x 600 mm x 800 mm
Medium - 1700 mm x 600mm x 800 mm
Large - 2100 mm x 600 mm x 800 mm
Bottom entry as standard
Front & rear lockable access
(standard system requires rear access)
Environmental
Operating Temperature 0 ºC to +40 ºC
Storage Temperature -15 ºC to +50 ºC
Cooling Fan assisted cooling fitted to all cabinets
as standard
Operating Humidity 0-95% RH, non-condensing
Operating Altitude 3000 metres without derating
Acoustic Noise <45 dBA at 1 metre
Ingress Protection Options from IP21 - IP54
EMC & Safety
Emissions EN55022 level B,
EN50091-2, level B, FCC Class B
ESD Immunity EN61000-4-2, level 3
Radiated Immunity EN61000-4-3, level 2
EFT/Burst EN61000-4-4, level 2
Surge EN61000-4-5, level 3
Safety Approvals EN50091-1-1, EN60240-1-1, EN60950, CE