DC-DC Converters
TRV1 Series, 1 Watt
Electrical Specification
Short Circuit Protection limited 0.5 sec.
Operating Temperature Range -40°C to +85°C (no derating)
I/O Isolation test voltage 3000VDC
Casing plastic (UL94V-0 rated)
Output Voltage and Current Ratings
MODEL INPUT OUTPUT OUTPUT RIPPLE & LINE LOAD EFF.
VOLTAGE VOLTAGE CURRENT NOISE REG. REG. (typ.)
TRV1-0511 5VDC 200mA 30mV pk-pk max. 1.2% 5% 86%
TRV1-0519 5VDC ±10% 9VDC 110mA 30mV pk-pk max. 1.2% 5% 86%
TRV1-0512 12VDC 84mA 30mV pk-pk max. 1.2% 5% 86%
TRV1-0513 15VDC 67mA 30mV pk-pk max. 1.2% 5% 86%
TRV1-1211 5VDC 200mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-1219 12VDC ±10% 9VDC 110mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-1212 12VDC 84mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-1213 15VDC 67mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-2411 5VDC 200mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-2419 24VDC ±10% 9VDC 110mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-2412 12VDC 84mA 30mV pk-pk max. 1.2% 3.5% 86%
TRV1-2413 15VDC 67mA 30mV pk-pk max. 1.2% 3.5% 86%
Mechanical and Connection Details
www.powersolve.co.uk
Pin Single Output
1 +Vin (Vcc)
2 -Vin (GND)
5 -Vout
7 +Vout
Features
Semi-regulated output
Industry standard pin out
High efficiency up to 86%
I/O isolation 3000VDC
Operating temperature range -40°C to +85°C
Dimensions in mm (inches)